|
T-Industrial-Duty Trolley Operator for Standard Lift Sectional Doors |
|
LOGIC 4.O TECHNOLOGY (L4)
Added Value
-
Built-in 3-channel, 315MHz radio receiver accepts up to 23 Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Maintenance Alert System™ establishes a routine maintenance schedule based on the number of cycles or calendar date. Includes self-diagnostic system that allows you to troubleshoot up to eight different error codes
-
Timer-to-Close allows programming in 1-sec or 15-sec increments and permits timed automatic door closure after the door reaches the full open position; requires monitored photo sensors, either CPS-U, CPS-UN4, or a 4-wire edge, using the CPS-EI edge interface
-
Thermal motor overload can be easily reset from the 3-button floor level control station
|

|
|
|
MT-Medium Duty Trolley Operator for Standard Lift Sectional Doors |
|
MEDIUM-DUTY LOGIC TECHNOLOGY
Added Value
-
UL325-2010 compliant Medium-Duty Logic programmable integrated circuit board
-
Built-in 3-channel, 315MHz radio receiver accepts up to 20 Chamberlain® Security+® or unlimited DIP switch remotes.
3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Programmable C2 or B2 wiring options (B2 requires CPS-U, CPS-UN4, or CPS-EI)
-
Integrated Timer-to-Close (TTC) allows programming from 5 to 60 seconds in 5-second increments. Allows for timed automatic door closure after the door reaches the full open position (Requires monitored safety devices, with CPS-U, CPS-UN4, or CPS-EI)
-
Integrated 90-second maximum run timer
-
UL325-2010 Monitored Entrapment Capability
-
Monitored protection against transient overvoltage conditions
-
3-button control station included
|

|
|
|
ATS-Advanced Trolley System Light-Duty Trolley Operator |
-
Automatic safety reverse/automatic door stop
-
Manual release in case of power failure
-
I-beam trolley trolley track
-
The Protector System non-impact infrared safety device
-
1-button control station
-
Standard with 14' rail
-
High-torque, industrial 1/2 HP, 115V single-phase motor with instant reverse and automatic reset thermal overload
-
1-year warranty
|

|
|
|
MH-Medium-Duty Hoist Operator
|
|
MEDIUM-DUTY LOGIC TECHNOLOGY
Added Value
-
UL325-2010 compliant Medium-Duty Logic programmable integrated circuit board
-
Built-in 3-channel, 315MHz radio receiver accepts up to 20 Chamberlain® Security+® or unlimited DIP switch remotes.
3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Programmable C2 or B2 wiring options (B2 requires CPS-U, CPS-UN4, or CPS-EI)
-
Integrated Timer-to-Close (TTC) allows programming from 5 to 60 seconds in 5-second increments. Allows for timed automatic door closure after the door reaches the full open position (Requires monitored safety devices, with CPS-U, CPS-UN4, or CPS-EI)
-
Integrated 90-second maximum run timer
-
UL325-2010 Monitored Entrapment Capability
-
Monitored protection against transient overvoltage conditions
-
3-button control station included
|
 |
|
|
HJ-Industrial-Duty Hoist/Jackshaft Operator |
|
LOGIC 4.0 TECHNOLOGY (L4)
Added Value
-
Built-in 3-channel, 315MHz radio receiver accepts up to 23 Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Maintenance Alert System™ establishes a routine maintenance schedule based on the number of cycles or calendar date. Includes self-diagnostic system that allows you to troubleshoot up to eight different error codes
-
Timer-to-Close allows programming in 1-sec or 15-sec increments and permits timed automatic door closure after the door reaches the full open position; requires monitored photo sensors, either CPS-U or CPS-UN4, or a 4-wire edge, using the CPS-EI edge interface
-
Thermal motor overload can be easily reset from the 3-button floor level control station
|
 |
|
|
H-Industrial-Duty Hoist Operator |
|
LOGIC 4.0 TECHNOLOGY (L4)
Added Value
-
Built-in 3-channel, 315MHz radio receiver accepts up to 23 Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Maintenance Alert System™ establishes a routine maintenance schedule based on the number of cycles or calendar date. Includes self-diagnostic system that allows you to troubleshoot up to eight different error codes
-
Timer-to-Close allows programming in 1-sec or 15-sec increments and permits timed automatic door closure after the door reaches the full open position; requires monitored photo sensors, either CPS-U or CPS-UN4, or a 4-wire edge, using the CPS-EI edge interface
-
Thermal motor overload can be easily reset from the 3-button floor level control station
|
 |
|
|
MJ-Medium-Duty Jackshaft Operator |
|
MEDIUM-DUTY LOGIC TECHNOLOGY
Added Value
-
UL325-2010 compliant Medium-Duty Logic programmable integrated circuit board
-
Built-in 3-channel, 315MHz radio receiver accepts up to 20 Chamberlain® Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Programmable C2 or B2 wiring options (B2 requires CPS-U, CPS-UN4, or CPS-EI)
-
Integrated timer-to-close (TTC) allows programming from 5 to 60 seconds in 5-second increments. Allows for timed automatic door closure after the door reaches the full open position (Requires monitored safety devices, with CPS-U, CPS-UN4, or CPS-EI)
-
Integrated 90-second maximum run timer
-
UL325-2010 Monitored Entrapment capability
-
Monitored protection against transient overvoltage conditions
-
3-button control station included
|

|
|
|
J-Industrial Duty Jackshaft Operator |
|
LOGIC 4.0 TECHNOLOGY (L4)
Added Value
-
Built-in 3-channel, 315MHz radio receiver accepts up to 23 Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Maintenance Alert System™ establishes a routine maintenance schedule based on the number of cycles or calendar date. Includes self-diagnostic system that allows you to troubleshoot up to eight different error codes
-
Timer-to-Close allows programming in 1-sec or 15-sec increments and permits timed automatic door closure after the door reaches the full open position; requires monitored photo sensors, either CPS-U or CPS-UN4, or a 4-wire edge, using the CPS-EI edge interface
-
Thermal motor overload can be easily reset from the 3-button floor level control station
|
 |
|
|
DJ-Industrial-Duty Jackshaft Operator with Internal Door Lock Sensor |
|
LOGIC 4.0 TECHNOLOGY (L4)
Added Value
-
Built-in 3-channel, 315MHz radio receiver accepts up to 23 Security+® or unlimited DIP switch remotes. 3-button remotes can be programmed for OPEN/CLOSE/STOP operation
-
Maintenance Alert System™ establishes a routine maintenance schedule based on the number of cycles or calendar date. Includes self-diagnostic system that allows you to troubleshoot up to eight different error codes
-
Timer-to-Close allows programming in 1-sec or 15-sec increments and permits timed automatic door closure after the door reaches the full open position; requires monitored photo sensors, either CPS-U or CPS-UN4, or a 4-wire edge, using the CPS-EI edge interface
-
Thermal motor overload can be easily reset from the 3-button floor level control station
|

|